The ideal window R-value for New Zealand housing is one that meets or exceeds the H1 reference: R0.46 in climate zones 1–4 and R0.50 in zones 5–6 (H1/AS1 and H1/VM1, sixth edition). UNO Windows & Doors' UNO Thermal aluminium windows with double-glazed Low-E glass can achieve a construction R-value of R0.61 on a typical project with about 35 m² of windows and doors, and R0.83 with triple glazing.
There's no minimum window R-value; instead, your design is compared with a reference building. UNO Windows & Doors designs its own UNO Thermal aluminium window suite in-house and manufactures it in New Zealand. Enter your joinery into UNO Hub to generate project-specific construction R-values for your H1 assessment.
In light of the updated New Zealand Building Code H1 energy efficiency requirements, many architects and developers wonder which window frame materials are most suitable.
The updated standards mark a major step forward for our national standards but for those in the construction industry, it's a big adjustment.
To make it easier, this article outlines how good R-values are achieved and what it costs.
Last reviewed: November 2026
The New Zealand climate zones and reference R-values
Part of the H1 standards update was the introduction of a new set of climate zones. These six zones divide the country into areas with similar weather patterns and average temperatures. Refer to the map below to determine which zone your next project is in and then read on to find the applicable reference R-value.

Zones 1 and 2 – R0.46
In Northland, Auckland, Coromandel, Bay of Plenty, Hamilton, East Coast and Taranaki, the reference R-value for windows and doors is R0.46. The H1/AS1 generic values for double-glazed standard aluminium windows are R0.24–R0.39, so we recommend thermally broken aluminium frames, such as UNO Thermal, with double-glazed Low-E glass to meet or exceed the reference.
Zones 3 and 4 – R0.46
In Manawatu, Horowhenua, Wellington, Nelson, Marlborough, Chatham Islands, Central Plateau, Wairarapa, and the West Coast, the reference R-value is R0.46. To meet or exceed this, we recommend thermally broken aluminium frames and double-glazed low-E glass with a thermal spacer.
Zones 5 and 6 – R0.50
In Canterbury, Coastal Otago, Inland Otago, Southland, and Stewart Island, the reference R-value is R0.50. To meet or exceed this, we recommend thermally broken aluminium frames with argon-filled, double-glazed high-performance low-E glass. For example, Viridian Performatech or Metro Low-E Xtreme can be used with a thermally improved spacer.
How to meet or exceed the reference R-value
To meet or exceed the reference R-value, you need to consider three factors:
- Window & door configurations
- Glass type
- Product material (aluminium or uPVC)
Configurations
The design of the window and door units affects thermal performance. For example, with windows, you can choose between smaller or larger glass areas, and fixed or opening sashes. When using high performance Low-E glazing, the larger the proportion of glass area in relation to the area of frame, the better the R-value. To find out what configurations are most effective for your climate zone and project, speak to the UNO team.
Glass
For new residential projects, we recommend windows with argon-filled double glazing made with high-performance Low-E glass. For example, Viridian Lightbridge or Metro Low E Max.
Product material
The two most cost-effective options for window frames are uPVC and aluminium. With aluminium windows, you can choose between non-thermal frames and thermally-improved frames. The most popular choice in NZ is aluminium frames. Both aluminium and uPVC windows are low maintenance and customisable, but aluminium has smaller frames, greater glass area, and thus lets in more light, more durable, and has more colour choices. If you opt for aluminium, we recommend choosing thermally broken frames as they provide better insulation and acoustic performance. What gives aluminium windows a greater advantage is their longer lifespan: you will need to replace your uPVC windows sooner than aluminium.
How to calculate a building’s R-value
To determine the required R-value for your project, there are 2 different calculation methods to use.
Calculation method
- Refer to H1/AS1, the NZBC online calculator, or BRANZ calculator tool.
- Enter your proposed windows and doors into UNO Hub.
- Generate project-specific construction R-values based on the actual sizes, configurations and products being specified.
- Use these values within the Calculation Method as part of the wider H1 assessment.
When using the “calculation method”, you can use the tool from the NZBC online calculator to input all the square metre areas and construction R-values for each component. This will advise you of the heat loss from your building compared to the reference building and if you are compliant with the new standards.
This lets you play with the insulation numbers and gives you the ability to adjust and reduce insulation R-values in other areas, potentially saving you money.
Modelling method
- Refer to H1VM1 section D.
- Identify the construction R-values for the vertical windows and doors, opaque doors, and the solar heat gain coefficient for any glass in the proposed thermal envelope.
- Sign up to UNO Hub and enter your proposed windows and doors.
- UNO Hub generates the construction R-value report to support compliance with the code.
Our recommendation
We recommend using the calculation method as a minimum, provided the glazing area does not exceed 40% of the total wall area, because it can result in substantial savings in other areas. For example, you can reduce insulation in the roof, walls, and floors while still achieving a high overall R-value for the building.
While the calculation method is not required to address solar heat gain, it is important to consider that there is a potential for overheating in large glazed areas. To check this, the modelling method considers solar heat gain and external shading devices.
Use the step-by-step process in our H1 guide, then enter your proposed windows and doors into UNO Hub to generate the project-specific construction R-values needed for your H1 assessment.
Reduce overall heat loss and construction costs
Up to 40% of a home's heating energy is lost through windows, according to EECA. Double glazing can reduce this to 25% or less. So, if we can increase the window construction R-value, the overall building heat loss will improve dramatically.
If you were to increase the window R-value by a given amount, you would significantly reduce heat loss in the building. However, if you were to increase the roof R-value by the same amount, the reduction in heat loss would be less because it would still escape out the windows.
For example, let's compare the heat loss difference (W/K) when increasing the roof construction R-value by the same R-value on the windows:
| Area (m2) | Construction R-value | Heat lost (W/K) | Percentage saving on heat loss | |
| Roof | 140 | 6.6 | 21.2 | |
| Roof | 140 | 6.79 | 20.6 | |
| Reduction in heat loss by increasing the R-Value R0.19 | 0.6 | 2.8% | ||
| Window | 35 | 0.46 | 76.1 | |
| Window | 35 | 0.65 | 53.8 | |
| Reduction in heat loss by increasing the R-Value R0.19 | 22.3 | 29.3% | ||
If you lower the insulation level in the roof, walls, and floor, but ONLY after increasing the R-value of the windows, you can achieve substantial project savings. For example, if you reduce the roof R-value from R6.3 to R3.6, you can save more than 50% per square metre. Note: under H1/AS1 6th edition, you can lower other elements to balance the calculation, but not below the minimums of R2.6 for roofs, R1.0 for walls and R1.3 for floors other than slab-on-ground.
This also necessitates having your window construction R-value established as early as possible in the design phase of your project.
How to achieve higher R-values for aluminium windows
Since each project is unique, there is no one-size-fits-all maximum R-value. However, let’s consider an example where the total area for windows and doors is approximately 35 square metres, & had configurations as shown in the below images. Using the UNO thermal window suite and a double-glazed Low-E product with a Ug-value of 1.1, we can achieve a construction R-value of R0.61.
Taking it a step further, we can explore other double-glazed Low-E options, such as a product with a Ug value of 1.0. The same project could achieve an R-value of R0.65.
Furthermore, if we consider a triple-glazed option with a Ug-value of 0.6, we could achieve an R-value of R0.83. All three options sit above the R0.46 (zones 1–4) and R0.50 (zones 5–6) reference values for housing.
Please note that it is crucial to use our specialised software to verify the sizes and configurations throughout the building.
Window costs
Meeting H1 insulation standards costs more because of the high standard of materials required. However, the investment pays off in long-term energy efficiency.
In saying that, the cost of a window with a high R-value is similar to a window that only just meets the reference R-value. By opting for the higher R-value at the beginning, you will save significantly throughout the compliance process and in the long term.
Average supply costs for thermally insulated aluminium windows with Low-E double glazing are between $800 and $1,400 per square metre + GST. However, this depends on the following:
- Window & door configurations
- Hardware type
- Type of glass
- Quantity of safety glass required to comply with the Building Code
- Quantity of site glazing (typically for heavy units)
- Site access for site glazing of larger items
- Wind zone on the building site
Indicative supply cost only, as at November 2026. Not a quote: pricing depends on your project.
For more information on windows and doors, including specifications, download our window brochure and our door brochure.
Frequently asked questions
What is the ideal R-value for windows in New Zealand housing?
Under H1/AS1 and H1/VM1 (sixth edition), the reference R-value for windows and doors is R0.46 in climate zones 1–4 and R0.50 in zones 5–6, and there is no minimum window R-value. UNO Windows & Doors' UNO Thermal suite with double-glazed Low-E glass can achieve R0.61 on a typical project, and R0.83 with triple glazing. Generate project-specific construction R-values in UNO Hub.
Can thermally insulated aluminium window frames achieve a high R-value?
Yes. Thermally-broken aluminium windows can achieve high R-values when paired with the right glass product. For example, the UNO thermal window suite with double-glazed Low-E glass can achieve a significantly higher construction R-value than the H1/AS1 generic values for thermally broken aluminium (R0.30–R0.52, Table D.1.1.1).
Do thermally insulated aluminium window frames comply with the latest H1 requirements?
Yes, the UNO suite can exceed the H1 energy efficiency requirements, provided you choose the right configuration and combination of products. Compliance is assessed for the whole building, so confirm with your H1 calculation. Simply ask our experts for recommendations.
Which H1 editions apply from 27 November 2026?
From 27 November 2026, teams must show H1 compliance for housing using the H1/AS1 sixth edition (calculation method) or the H1/VM1 sixth edition (modelling method). The schedule method is not part of either document. For housing, the reference R-value for windows and doors is R0.46 in climate zones 1–4 and R0.50 in zones 5–6. There's no minimum window R-value; your design is compared with a reference building.
Ready to work through your window and door R-values? Enter your proposed joinery into UNO Hub to generate project-specific construction R-values and access the technical information you need in one place.
Disclaimer
The information in this article is provided for general information purposes only and reflects the Building Code documents and standards current at the "Last reviewed" date shown on this article. It does not constitute technical, engineering or legal guidance for any specific project. Building Code documents and standards are subject to change; readers should refer to the current version of the relevant document and confirm all requirements with their designer, engineer and Building Consent Authority before proceeding. Construction R-values and product performance are project-specific and should be confirmed using the values generated in UNO Hub for the project concerned. UNO Windows & Doors accepts no liability for any loss or outcome arising from reliance on, or interpretation of, the information provided.